Author: Geloni, G.
Paper Title Page
TUPOST046 Machine Learning Applied for the Calibration of the Hard X-Ray Single-Shot Spectrometer at the European XFEL 965
 
  • C. Grech, M.W. Guetg
    DESY, Hamburg, Germany
  • G. Geloni
    EuXFEL, Schenefeld, Germany
 
  Single-crystal monochromators are used in free electron lasers for hard x-ray self-seeding, selecting a very narrow spectral range of the original SASE signal for further amplification. When rotating the crystal around the roll and pitch axes, one can exploit several symmetric and asymmetric reflections as established by Bragg’s law. This work describes the implementation of a machine learning classifier to identify the crystal indices corresponding to a given reflection, and eventually calculate the difference between the photon energy as measured by a single-shot spectrometer and the actual one. The image processing techniques to extract the properties of the crystal reflection are described, as well as how this information is used to calibrate two spectrometer parameters.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOST046  
About • Received ※ 07 June 2022 — Revised ※ 14 June 2022 — Accepted ※ 24 June 2022 — Issue date ※ 09 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOPT014 The Status of the SASE3 Variable Polarization Project at the European XFEL 1029
 
  • S. Karabekyan, S. Abeghyan, M. Bagha-Shanjani, S. Casalbuoni, U. Englisch, W. Freund, G. Geloni, J. Grünert, S. Hauf, C. Holz, D. La Civita, J. Laksman, D. Mamchyk, M.P. Planas, F. Preisskorn, S. Serkez, H. Sinn, M. Wuenschel, M. Yakopov, C. Youngman
    EuXFEL, Schenefeld, Germany
  • P. Altmann, A. Block, W. Decking, L. Fröhlich, O. Hensler, T. Ladwig, D. Lenz, D. Lipka, R. Mattusch, N. Mildner, E. Negodin, J. Prenting, F. Saretzki, M. Schlösser, F. Schmidt-Föhre, E. Schneidmiller, M. Scholz, D. Thoden, T. Wamsat, T. Wilksen, T. Wohlenberg, M.V. Yurkov
    DESY, Hamburg, Germany
  • J. Bahrdt
    HZB, Berlin, Germany
  • M. Brügger, M. Calvi, S. Danner, R. Ganter, L. Huber, A. Keller, C. Kittel, X. Liang, S. Reiche, M.S. Schmidt, T. Schmidt, K. Zhang
    PSI, Villigen PSI, Switzerland
  • D.E. Kim
    PAL, Pohang, Republic of Korea
  • Y. Li
    IHEP, People’s Republic of China
 
  The undulator systems at the European XFEL consist of two hard X-ray systems, SASE1 and SASE2, and one soft X-ray system, SASE3. All three systems are equipped with planar undulators using permanent neodymium magnets. These systems allow the generation of linearly polarized radiation in the horizontal plane. In order to generate variable polarization radiation in the soft X-ray range, an afterburner is currently being implemented behind the SASE3 planar undulator system. It consists of four APPLE-X helical undulators. The project, called SASE 3 Variable Polarization, is close to being put into operation. All four helical undulators have been installed in the tunnel during the 2021-2022 winter shutdown. This paper describes the status of the project and the steps toward its commissioning. It also presents lessons learned during the implementation of the project.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOPT014  
About • Received ※ 02 June 2022 — Revised ※ 12 June 2022 — Accepted ※ 13 June 2022 — Issue date ※ 05 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)