Author: Weilbach, T.
Paper Title Page
MOPOPT029 Longitudinal Phase Space Benchmarking for PITZ Bunch Compressor 310
 
  • A. Lueangaramwong, Z. Aboulbanine, G.D. Adhikari, N. Aftab, P. Boonpornprasert, G.Z. Georgiev, J. Good, M. Groß, C. Koschitzki, M. Krasilnikov, X.-K. Li, O. Lishilin, D. Melkumyan, H.J. Qian, G. Shu, F. Stephan, G. Vashchenko, T. Weilbach
    DESY Zeuthen, Zeuthen, Germany
  • N. Chaisueb
    Chiang Mai University, Chiang Mai, Thailand
 
  The longitudinal phase space characteristics of space-charge dominated electron beams are keys to achieving bunch compression for the accelerator-based THz source at the Photo Injector Test facility at DESY in Zeuthen (PITZ). Such a THz source is proposed as a prototype for an accelerator-based THz source for pump-probe experiments at the European XFEL. A start-to-end simulation has suggested the settings of the phase of booster linear accelerator manipulating longitudinal beam characteristics to optimize the performance of the THz FEL. Although beam diagnostics after compression at PITZ are limited, the longitudinal beam characteristics as a function of the booster phase have been measured and compared with the corresponding simulations. The benchmark involves measurements of longitudinal phase space distribution for bunch charges up to 2 nC. The measurement technique assigned uses 50-um slits to achieve higher momentum and time resolution (1.8 keV/c and 0.5 ps, respectively).  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-MOPOPT029  
About • Received ※ 07 June 2022 — Revised ※ 10 June 2022 — Accepted ※ 17 June 2022 — Issue date ※ 18 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOPT016 Status of the THz@PITZ Project - The Proof-of-Principle Experiment on a THz SASE FEL at the PITZ Facility 1033
 
  • T. Weilbach, P. Boonpornprasert, G.Z. Georgiev, G. Koss, M. Krasilnikov, X.-K. Li, A. Lueangaramwong, F. Mueller, A. Oppelt, S. Philipp, F. Stephan
    DESY Zeuthen, Zeuthen, Germany
 
  Funding: This work was supported by the European XFEL research and development program.
In order to allow THz pump/X-ray probe experiments at full bunch repetition rate for users at the European XFEL, the Photo Injector Test Facility at DESYin Zeuthen (PITZ) is building a prototype of an accelerator-based THz source. The goal is to generate THz SASE FEL radiation with a mJ energy level per bunch using an undulator driven by the electron beam from PITZ. Therefore, the existing PITZ beam line is extended into a tunnel annex downstream of the existing accelerator tunnel. The final design of the beam line extension consists of a bunch compressor, a collimation system and a beam dump in the PITZ tunnel. In the tunnel annex one LCLS-I undulator is installed for the production of the THz radiation with a quadrupole triplet in front of it for matching the beam parameters for the FEL process. Behind the undulator two screen stations couple out the THz radiation, for measurements of bunch compression, pulse energy or spatial distribution. A dipole separates the electron from the THz beam and a quadrupole doublet transports the electron beam to the beam dump. The installation progress will be presented.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOPT016  
About • Received ※ 07 June 2022 — Revised ※ 15 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 25 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THOYGD2
Experimental Slice Emittance Reduction at PITZ Using Laser Pulse Shaping  
 
  • R. Niemczyk, Z. Aboulbanine, G.D. Adhikari, N. Aftab, P. Boonpornprasert, G.Z. Georgiev, J. Good, M. Groß, C. Koschitzki, X.-K. Li, O. Lishilin, D. Melkumyan, S.K. Mohanty, A. Oppelt, H.J. Qian, H. Shaker, G. Shu, F. Stephan, T. Weilbach
    DESY Zeuthen, Zeuthen, Germany
  • M.E. Castro Carballo, M. Krasilnikov, G. Vashchenko
    DESY, Hamburg, Germany
  • W. Hillert
    University of Hamburg, Institut für Experimentalphysik, Hamburg, Germany
 
  Free-electron lasers in the X-ray regime require a high-brightness electron beam, i.e. an electron beam with high current and low transverse emittance. At the Photo Injector Test facility at DESY in Zeuthen (PITZ) high-brightness electron sources are optimized for the use at FLASH and European XFEL. A low transverse emittance of the electron beam’s central part, which is assumed to be the lasing slices, is of particular interest for the efficient FEL operation. Over the past years a slice emittance measurement scheme has been developed at PITZ which employs an rf deflector and additional quadrupole magnets along the beamline to the standard measurement procedure for the projected emittance (single-slit scan). It allows measuring the slice emittance in a high-brightness photo injector. Transversely flat-top shaped laser pulses of different temporal distributions (Gaussian and flat-top) have been used to emit electrons, as well as transversely-truncated Gaussian laser pulses with temporal Gaussian shape. The paper shows that the lowest slice emittance in the injector is reached with a temporal flattop shape, or when using a transversely-truncated Gaussian shape.  
slides icon Slides THOYGD2 [2.045 MB]  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)