THPOST005 Tracking Dynamic Aperture in the iRCMS Hadrontherapy Synchrotron 2442
 
  • F. Méot, P.N. Joshi, N. Tsoupas
    BNL, Upton, New York, USA
  • J.P. Lidestri, M.R. Subramanian
    Best Medical International, Springfield, USA
 
  Funding: Work supported by a TSA between Best Medical International and Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy.
Dynamic aperture (DA) studies which are part of the ion Rapid Cycling Medical Synchrotron (iRCMS) lattice design have been undertaken. They are aimed at supporting on-going plans to launch the production of the six magnetic sectors which comprise the iRCMS racetrack arcs. The main bend magnetic gap is tight, so allowing smaller volume magnets and resulting in a compact ring. The DA happens to be commensurate with the mechanical aperture, thus tracking accuracy is in order. In that aim, DA tracking uses the OPERA field maps of the six 60 degree magnetic sectors of the arcs. Simulation outcomes are summarized here.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-THPOST005  
About • Received ※ 03 June 2022 — Revised ※ 18 June 2022 — Accepted ※ 22 June 2022 — Issue date ※ 02 July 2022