Author: Raubenheimer, T.O.
Paper Title Page
TUPOPT046 Electron Transport for the LCLS-II-HE Low Emittance Injector 1103
 
  • Y.M. Nosochkov, C. Adolphsen, R. Coy, C.E. Mayes, T.O. Raubenheimer, M.D. Woodley
    SLAC, Menlo Park, California, USA
 
  Funding: Work supported by the Department of Energy Contract DE-AC02-76SF00515.
The Low Emittance Injector (LEI) is a recent addition to the LCLS-II High Energy (LCLS-II-HE) Project under design at SLAC National Accelerator Laboratory. It will provide a second beam source capable of producing a low emittance electron beam that increases the XFEL photon energy reach to 20 keV. The LEI will include an SRF electron gun, a buncher system, a 1.3 GHz cryomodule, and a beam transport system with a connection to the LCLS-II beamline and a stand-alone diagnostic line. The LEI transport beamlines and diagnostic are discussed.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOPT046  
About • Received ※ 08 June 2022 — Accepted ※ 17 June 2022 — Issue date ※ 08 July 2022  
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPOMS053 Start-to-End Simulations of the LCLS-II HE Free Electron Laser 1549
 
  • D.B. Cesar, G. Marcus, H.-D. Nuhn, T.O. Raubenheimer
    SLAC, Menlo Park, California, USA
  • J. Qiang
    LBNL, Berkeley, California, USA
 
  Funding: This work is supported in part by DOE Contract No. DE-AC02-76SF00515
In this proceeding we present start-to-end simulations of the LCLS-II-HE free electron laser. The HE project will extend the LCLS-II superconducting radio-frequency (SRF) linac from 4 GeV to 8 GeV in order to produce hard x-rays from the eponymous hard x-ray undulators (26 mm period). At the same time, soft x-ray performance is preserved (and extended into the tender regime) by using longer period undulators (56 mm period) than were originally built for LCLS-II (39 mm period). Here we use high-fidelity numerical particle simulations to study the performance of several SASE beamline configurations, and compare the resulting x-ray energy, power, duration, and transverse properties. Using the LCLS-II normal-conducting gun, we find that the x-ray pulse energy drops off rapidly above ~15 keV, while using the lower emittance beam from a proposed SRF gun, we improve the cutoff to ~20 keV.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOMS053  
About • Received ※ 08 June 2022 — Revised ※ 13 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 21 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPOST010 Controlling e+/e Circular Collider Bunch Intensity by Laser Compton Scattering 1695
 
  • F. Zimmermann
    CERN, Meyrin, Switzerland
  • T.O. Raubenheimer
    SLAC, Menlo Park, California, USA
 
  Funding: This project receives funding from the European Union’s H2020 Framework Programme under grant agreement no. 951754 (FCCIS).
In the future circular electron-positron collider "FCC-ee", the intensity of colliding bunches must be tightly controlled, with a maximum charge imbalance between collision partner bunches of less than 3-5%. Laser Compton back scattering could be used to adjust and fine-tune the bunch intensity. We discuss a possible implementation and suitable laser parameters.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-WEPOST010  
About • Received ※ 08 June 2022 — Revised ※ 14 June 2022 — Accepted ※ 23 June 2022 — Issue date ※ 03 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPOPT063 The FCCee Pre-Injector Complex 2007
 
  • P. Craievich, B. Auchmann, S. Bettoni, H.-H. Braun, M. Duda, D. Hauenstein, E. Hohmann, R. Ischebeck, P.N. Juranič, J. Kosse, G.L. Orlandi, M. Pedrozzi, J.-Y. Raguin, S. Reiche, S.T. Sanfilippo, M. Schaer, N. Vallis, R. Zennaro
    PSI, Villigen PSI, Switzerland
  • F. Alharthi, I. Chaikovska, S. Ogur
    Université Paris-Saclay, CNRS/IN2P3, IJCLab, Orsay, France
  • W. Bartmann, M. Benedikt, M.I. Besana, M. Calviani, S. Döbert, Y. Dutheil, O. Etisken, J.L. Grenard, A. Grudiev, B. Humann, A. Latina, A. Lechner, K. Oide, A. Perillo-Marcone, H.W. Pommerenke, R.L. Ramjiawan, Y. Zhao, F. Zimmermann
    CERN, Meyrin, Switzerland
  • A. De Santis
    INFN/LNF, Frascati, Italy
  • Y. Enomoto, K. Furukawa, K. Oide
    KEK, Ibaraki, Japan
  • O. Etisken
    Kirikkale University, Kirikkale, Turkey
  • C. Milardi
    LNF-INFN, Frascati, Italy
  • T.O. Raubenheimer
    SLAC, Menlo Park, California, USA
  • N. Vallis
    EPFL, Lausanne, Switzerland
 
  The international FCC study group published in 2019 a Conceptual Design Report for an electron-positron collider with a centre-of-mass energy from 90 to 365 GeV with a beam currents of up to 1.4 A per beam. The high beam current of this collider create challenging requirements on the injection chain and all aspects of the linac need to be carefully reconsidered and revisited, including the injection time structure. The entire beam dynamics studies for the full linac, damping ring and transfer lines are major activities of the injector complex design. A key point is that any increase of positron production and capture efficiency reduces the cost and complexity of the driver linac, the heat and radiation load of the converter system, and increases the operational margin. In this paper we will give an overview of the status of the injector complex design and introduce the new layout that has been proposed by the study group working in the context of the CHART collaboration. In this framework, furthermore, we also present the preliminary studies of the FCC-ee positron source highlighting the main requirements and constraints.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-WEPOPT063  
About • Received ※ 11 June 2022 — Revised ※ 14 June 2022 — Accepted ※ 17 June 2022 — Issue date ※ 29 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)