Paper | Title | Page |
---|---|---|
TUPOMS038 | RFQ NEWGAIN: RF and Thermomechanical Design | 1510 |
|
||
Funding: Agence Nationale de la Recherche (ANR) A new injector called NEWGAIN will be added to the SPIRAL2 Linear Accelerator (LINAC), in parallel with the existing one. It will be mainly composed of an ion source and a Radio Frequency Quadrupole (RFQ) connected to the superconductive LINAC of SPIRAL2. The new RFQ will accelerate at 88.05 MHz particles with charge-over-mass ratio (Q/A) between 1/3 and 1/7, from 10 keV/u up to 590 keV/u. It consists of a 4-vane resonant cavity with a total length of 7 m. It is a CW machine that has to show stable operation, provide the request availability, have the minimum losses in order to provide the highest current to the superconductive LINAC and show the best quality/cost ratio. This paper will present the preliminary RF design and the thermomechanical study for this RFQ. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOMS038 | |
About • | Received ※ 08 June 2022 — Revised ※ 10 June 2022 — Accepted ※ 13 June 2022 — Issue date ※ 27 June 2022 | |