Author: Lee, S.H.
Paper Title Page
MOPOPT037 Beam Measurement and Application of the Metal Vapor Vacuum Arc Ion Source at KOMAC 328
 
  • S.H. Lee, H.S. Kim, H.-J. Kwon
    KOMAC, KAERI, Gyeongju, Republic of Korea
 
  Funding: This work has been supported through KOMAC operation fund of KAERI by MSIT (Ministry of Science and ICT) and the NRF (National Research Foundation) of Korea grant fund the Korea government (MSIT).
The metal ion beam facility is developed based on the MEVVA* ion source at the KOMAC**. The MEVVA ion source has advantage that it can be extract almost metal ion species as well as high current ion beam. After the installation, we measured beam properties such as peak beam current, beam profile depending on the operation condition. The average charge state is measured in order to estimate the total dose. We evaluate the beam stability through the long-term beam extraction, and the measured the cathode erosion rate too. In addition, as one of the application fields, we irradiate the metal beam on the cathode of the fuel cell and measured the performance. In this paper, the beam measurement results, are summarized and fuel cell performances after metal beam irradiation are discussed.
*Korea Multi-purpose of Accelerator Complex
**Metal Vapor Vacuum Arc
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-MOPOPT037  
About • Received ※ 08 June 2022 — Revised ※ 13 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 21 June 2022