Author: Cheng, C.M.
Paper Title Page
THPOTK037 Measurement of the Photon Stimulated Desorption for Various Vacuum Tubes at a Beam Line of TLS 2847
 
  • G.Y. Hsiung, C.M. Cheng
    NSRRC, Hsinchu, Taiwan
  • R. Valizadeh
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
 
  For most light sources, the synchrotron radiation (SR) hit on the beam ducts or absorbers results in higher pressure rise and the consequent higher radiation level through the commissioning stage. Various surface treatments, e.g. chemical cleaning, oil-free machining, NEG-coating, etc., for the beam ducts or absorbers have been developed worldwide for mitigating the yield of Photon Stimulated Desorption (PSD). A beam line, BL19B, of 1.5 GeV Taiwan Light Source (TLS) has been modified to measure the PSD-yield of the vacuum tubes. The white light of BL19B covers the critical length at 2.14 keV is suitable for generating higher yield of the photo-electrons (PEY) and the consequent PSD-yield to be measured can be resolved wide range of 10-2 ~ 10-7 molecules/photon. The PSD-outgas, measured by RGA, contains the typical H2, CO, CO2, hydrocarbons, and Kr from NEG-coating, alcohol from ethanol machined surface, in some cases. The effect of beam-cleaning reflects the PSD-molecules generated from the SR-irradiated surface. The comparison of the PSD for the various vacuum tubes will be described in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-THPOTK037  
About • Received ※ 08 June 2022 — Revised ※ 15 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 08 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)