Paper |
Title |
Page |
MOPOPT045 |
Beam Loss Localisation with an Optical Beam Loss Monitor in the CLEAR Facility at CERN |
351 |
SUSPMF091 |
|
|
- S. Benítez Berrocal, E. Effinger, J.C. Esteban Felipe, W. Farabolini, P. Korysko, A.T. Lernevall, B. Salvachúa
CERN, Meyrin, Switzerland
- M. Chen
University of Huddersfield, Huddersfield, United Kingdom
|
|
|
A prototype of a Beam Loss Monitor based on the detection of Cherenkov light in optical fibres is being developed to measure beam losses in the CERN Super Proton Synchrotron. Several testing campaigns have been planned to benchmark the simulations of the system and test the electronics in the CLEAR facility at CERN. During the first campaigns, the emission of Cherenkov light inside optical fibres and the photodetector characterisation were studied. Fibre-based Beam Loss monitors continuously monitor beam losses over long distances. The localisation of the beam loss could be calculated from the timing of the signals generated by the photosensors coupled at both ends of the optical fibre. The experimental results of an optical fibre Beam Loss Monitor installed in the CLEAR facility are reported in this paper.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2022-MOPOPT045
|
|
About • |
Received ※ 03 June 2022 — Revised ※ 12 June 2022 — Accepted ※ 13 June 2022 — Issue date ※ 24 June 2022 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|