Author: Ash, R.
Paper Title Page
TUPOPT047 Progress Report on Population Inversion X-Ray Laser Oscillator at LCLS 1107
 
  • A. Halavanau, R. Alonso-Mori, A. Aquila, U. Bergmann, F.-J. Decker, F. Fuller, M. Liang, A.A. Lutman, R.A. Margraf, R.H. Paul, C. Pellegrini
    SLAC, Menlo Park, California, USA
  • R. Ash, N.B. Welke
    UW-Madison/PD, Madison, Wisconsin, USA
  • A.I. Benediktovitch
    DESY, Hamburg, Germany
  • S.C. Krusic
    JSI, Ljubljana, Slovenia
  • N. Majernik, P. Manwani, J.B. Rosenzweig
    UCLA, Los Angeles, California, USA
  • R. Robles
    Stanford University, Stanford, California, USA
  • N. Rohringer
    Max Planck Institute for the Physics of Complex Systems, Dresden, Germany
 
  We report the progress in the design and construction of a population inversion x-ray laser oscillator (XLO) using LCLS as an x-ray laser pump, being developed by a SLAC, CFEL, University of Hamburg (Germany), University of Wisconsin, Josef Stefan Institute (Slovenia) and UCLA collaboration. In this proceeding, we will present the latest XLO design and numerical simulations substantiated by our first experimental results. In our next experimental step XLO will be tested on the Coherent X-ray Imaging (CXI) end-station at LCLS as a two pass Regenerative Amplifier operating at the Copper Kα1 photon energy of 8048 eV. When built, XLO will generate fully coherent transform limited pulses with about 50 meV FWHM bandwidth. We expect the XLO will pave the way for new user experiments, e.g. in inelastic x-ray scattering, parametric down conversion, quantum science, x-ray interferometry, and external hard x-ray XFEL seeding.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-TUPOPT047  
About • Received ※ 12 June 2022 — Revised ※ 14 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 24 June 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPOTK053 Foiled Again: Solid-State Sample Delivery for High Repetition Rate XFELs 2899
 
  • N. Majernik, N. Inzunza, P. Manwani, J.B. Rosenzweig
    UCLA, Los Angeles, California, USA
  • R.B. Agustsson, A. Moro
    RadiaBeam, Santa Monica, California, USA
  • R. Ash, N.B. Welke
    UW-Madison/PD, Madison, Wisconsin, USA
  • U. Bergmann, A. Halavanau, C. Pellegrini
    SLAC, Menlo Park, California, USA
 
  Funding: Department of Energy DE-SC0009914 and DE-AC02-76SF00515
XFELs today are capable of delivering high intensity pulse trains of x-rays with up-to MHz to sub-GHz frequency. These x-rays, when focused, can ablate a sample in a single shot, requiring the sample material to be replaced in time for the next shot. For some applications, especially serial crystallography, the sample may be renewed as a dilute solution in a high speed jet. Here, we describe the development and characterization of a system to deliver solid state sample material to an XFEL nanofocus. The first application of this system will be an x-ray laser oscillator operating at the copper Kα line with a ~30 ns cavity.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2022-THPOTK053  
About • Received ※ 06 June 2022 — Revised ※ 15 June 2022 — Accepted ※ 16 June 2022 — Issue date ※ 02 July 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)