JACoW logo

Journals of Accelerator Conferences Website (JACoW)

JACoW is a publisher in Geneva, Switzerland that publishes the proceedings of accelerator conferences held around the world by an international collaboration of editors.


RIS citation export for MOPOMS040: Radiation Shielding Design for the X-Band Laboratory for Radio-Frequency Test Facility - X-Lab - at the University of Melbourne

TY  - CONF
AU  - Volpi, M.
AU  - Banon-Caballero, D.
AU  - Boronat, M.
AU  - Catalán Lasheras, N.
AU  - Dowd, R.T.
AU  - Rassool, R.P.
AU  - Sheehy, S.L.
AU  - Taylor, G.
AU  - Williams, S.D.
ED  - Zimmermann, Frank
ED  - Tanaka, Hitoshi
ED  - Sudmuang, Porntip
ED  - Klysubun, Prapong
ED  - Sunwong, Prapaiwan
ED  - Chanwattana, Thakonwat
ED  - Petit-Jean-Genaz, Christine
ED  - Schaa, Volker R.W.
TI  - Radiation Shielding Design for the X-Band Laboratory for Radio-Frequency Test Facility - X-Lab - at the University of Melbourne
J2  - Proc. of IPAC2022, Bangkok, Thailand, 12-17 June 2022
CY  - Bangkok, Thailand
T2  - International Particle Accelerator Conference
T3  - 13
LA  - english
AB  - Here we report radiation dose estimates calculated for the X-band Laboratory for Accelerators and Beams (X-LAB) under construction at the University of Melbourne (UoM). The lab will host a CERN X-band test stand containing two 12 GHz 6 MW klystron amplifiers. By power combination through hybrid couplers and the use of pulse compressors, up to 50 MW of peak power can be sent to any of to either of the two test slots at pulse repetition rates up to 400 Hz. The test stand is dedicated to RF conditioning and testing CLIC’s high gradient accelerating structures beyond 100 MV/m. This paper also gives a brief overview of the general principles of radiation protection legislation; explains radiological quantities and units, including some basic facts about radioactivity and the biological effects of radiation; and gives an overview of the classification of radiological areas at X-LAB, radiation fields at high-energy accelerators, and the radiation monitoring system used at X-LAB. The bunker design to achieve a dose rate less than annual dose limit of 1 mSv is also shown.
PB  - JACoW Publishing
CP  - Geneva, Switzerland
SP  - 724
EP  - 727
KW  - radiation
KW  - electron
KW  - controls
KW  - simulation
KW  - operation
DA  - 2022/07
PY  - 2022
SN  - 2673-5490
SN  - 978-3-95450-227-1
DO  - doi:10.18429/JACoW-IPAC2022-MOPOMS040
UR  - https://jacow.org/ipac2022/papers/mopoms040.pdf
ER  -